TROUBLESHOOTING
Before calling Speakman Company for service, please run through the following checklist of troubleshooting steps. It
may be necessary to turn off the hot and cold water supply stops before proceeding to work on the Sensor Faucet.
Faucet Operation
If water flow from the faucet decreases
1. Make sure the supply stops are open.
2. Ensure both the hot and cold water Temperature Adjusters are not in the closed position (to open, screw out the hot
and cold water Temperature Adjusters (counter-clockwise direction)
3. Check that the In-line Filter in the Solenoid body is not blocked with debris. Remove slotted filter screw from the
Solenoid Body and rinse filter screen with clean water. Reassemble the filters, open stops, and check water flow.
Stops must be off when filters are removed.
4. Remove the outlet device (Aerator) from the spout using the outlet wrench. Operate the faucet with outlet device
removed. If water flow is acceptable, disassemble the outlet device and rinse components with clean water.
5. If 1), 2), 3), or 4) do not resolve the problem, call Speakman Company Customer Service for assistance.
If no water flows from the faucet
If you can hear clicking sound of solenoid opening, but no water flows
1. Check to see that the hot and cold water wall stops are completely open.
2. Check that the connectors are correctly connected to the solenoid (Yellow), to Power Module (red) and the
transformer (Black)
3. Activation light blinks continuously, even when faucet is not in use. This continuous blinking of the activation light
indicates that the batteries inside of the sensor module have low voltages and need to be replaced.
4. Check to see that the In-Line Filter in the Solenoid is not blocked.
If you do not hear a clicking sound from the solenoid and water does not flow
Disconnect the existing sensor module and connect a new module directly to the solenoid Power Supply
Transformer. Activate the new sensor module and check for water flow. If the water flows, disconnect the new module
and reconnect the old module and activate. If the old module still does not work, obtain a replacement module through
Speakman Customer Service.
If Batteries have been replaced but unit still fails to operate
1. Check battery polarity and electrical connection. Make sure wire plugs are fully inserted into sockets.
2. If faucet does not operate, replace existing sensor module with one you know to be functioning.
3. If faucet operates, contact Speakman Company at 800-537-2107 for a replacement sensor module.
4. If faucet still does not operate, call Speakman Company at 800-537-2107 and ask for the Solenoid Repair Kit, Part
No. RPG76-0039, to be shipped to you. Once the kit is received, shut off the hot and cold water supplies to the
faucet. Remove sensor module bracket and sensor module. Next, remove the four (4) screws that hold the coil
plastic case to the solenoid body and follow the instructions supplied with the kit. After replacing all parts supplied
in the kit, reassemble the faucet, open stops, and test the faucet.
If the faucet activates but will not shut-off
Contact Speakman Company at 800-537-2107