Installation

92-2840-R2
15of 18
MO (Manual Override ) HOSE INSTALLATION INSTRUCTIONS
For ease of installation attach hoses to ACM (above counter mixer) and MO (manual override) diverter
before installing under the sink.
1. Attach hot supply hose 1 to inlet ports of mixer (H port) 1 either ACM or UCM.
2. Attach cold supply hose 2 to inlet ports of mixer (C port) 2 either ACM or UCM.
3. Connect one end of diverter supply hose 3 to the Elbow outlet 3 on ACM or TEE outlet 3 on UCM.
Connect opposite end of hose 3 to the inlet port 3 of the MO Diverter valve.
4. Connect one end of the diverter discharge hose 4 to the outlet port 4 on the MO diverter valve.
Connect opposite end of hose 4 to by-pass port 4 of the Solenoid valve.
5. Connect one end of Solenoid supply hose 5 to the outlet port 5 on ACM or TEE outlet 5 on UCM.
Connect opposite end of hose 5 to the inlet port 5 of the Solenoid valve.
MO ACM UCM