Installation
92-2840-R2
11of 18
MO (manual override) Installation
(Also see page 14)
1. First insert the Thin Nut on the Faucet shank a little higher.
2. Insert Mount bracket and tighten the Solenoid Nut. (dry connection only)
3. Lower the Thin Nut onto bracket
4. Slip compression spring onto MO spindle
5. With O-Ring attached to the Spacer, slip Spacer and Bearing Sleeve onto spindle
6. With the lock washer and screw inside the Handle, properly position Handle onto Spindle.
7. Push Handle down onto Spindle to compress the spring and tighten the screw.
8. Snap Index Button into Handle
9. The water supply splits into Tee, and one exit hose goes to Solenoid and the other hose goes to bottom of MO
10. Form the side of MO the by-pass hose goes to the upper side of Solenoid discharge for manually controlled side
NOTE: For MO is used a Solenoid with a by-pass branch at its outlet. Use a Tee to split the supply water in 2 sides