CARE & CLEANING
Your SENSORFLO faucet is designed and engineered in accordance with the highest quality and
performance standards. With proper care it will provide years of hygienic and trouble free service.
Periodically the faucet will require some minor maintenance to keep it performing at peak performance.
The sensor module has a built-in low battery indicator light. This light will come on when the faucet
has approximately 10% of battery life. To replace the batteries follow the installation instructions
above.
Periodically clean the Solenoid Filter.
The polished chrome finish of your faucet should be cleaned using mild soap and warm water.
Dry immediately with a soft, clean cloth for best results.
NEVER use abrasive cleaners, chemicals, alcohol or other solvents. They may damage the surfaces of
the non-chrome plated finishes.
TROUBLESHOOTING
Before calling Speakman Company for service, please run through the following checklist of troubleshooting
steps. It may be necessary to turn off the hot and cold water supply stops before proceeding to work on the
Sensor Faucet.
Faucet Operation
If water flow from the faucet decreases
1. Make sure the supply stops are open.
2. Ensure both the hot and cold water Temperature Adjusters are not in the closed position (to open, screw out
the hot and cold water Temperature Adjusters (counter-clockwise direction)
3. Check that the In-line Filter in the Solenoid body is not blocked with debris. Remove slotted filter screw
from the Solenoid Body and rinse filter screen with clean water. Reassemble the filters, open stops, and
check water flow. Stops must be off when filters are removed.
4. Remove the outlet device (Aerator) from the spout using the outlet wrench. Operate the faucet with outlet
device removed. If water flow is acceptable, disassemble the outlet device and rinse components with clean
water.
5. If 1), 2), 3), or 4) do not resolve the problem, call Speakman Company Customer Service for assistance.
If no water flows from the faucet
If you can hear clicking sound of solenoid opening, but no water flows
1. Check to see that the hot and cold water wall stops are completely open.
2. Check that the connectors are correctly connected to the solenoid (Yellow), to Power Module (red) and the
transformer (Black)
3. Activation light blinks continuously, even when faucet is not in use. This continuous blinking of the
activation light indicates that the batteries inside of the sensor module have low voltages and need to be
replaced.
4. Check to see that the In-Line Filter in the Solenoid is not blocked.
If you do not hear a clicking sound from the solenoid and water does not flow
Disconnect the existing sensor module and connect a new module directly to the solenoid Power Supply
Transformer. Activate the new sensor module and check for water flow. If the water flows, disconnect the new
module and reconnect the old module and activate. If the old module still does not work, obtain a replacement
module through Speakman Customer Service.