MO (manual override) Installation
8. First insert the Thin Nut on the Faucet shank a little higher.
9. Insert Mount bracket and tighten the Solenoid Nut. (dry connection only)
10. Lower the Thin Nut onto bracket
11. Slip compression spring onto MO spindle
12. With O-Ring attached to the Spacer, slip Spacer and Bearing Sleeve onto spindle
13. With the lock washer and screw inside the Handle, properly position Handle onto Spindle.
14. Push Handle down onto Spindle to compress the spring and tighten the screw.
15. Snap Index Button into Handle
16. The water supply splits into Tee, and one exit hose goes to Solenoid and the other hose goes to bottom of
MO
17. Form the side of MO the by-pass hose goes to the upper side of Solenoid discharge for manually controlled
side
18. NOTE: For MO is used a Solenoid with a by-pass branch at its outlet. Use a Tee to split the supply water in
2 sides