Installation
SPEAKMAN
®
400 Anchor Mill Rd. New Castle, DE 19720 Phone: 800-537-2107 Fax: 800-977-2747
01/13 Visit us on the web at www.speakmancompany.com 92-S-91XX-98XX-R3
5of 16
Install 3/8”compression fitting hoses to the UCM
(under counter mixing valve). The hot and cold
sides are marked H and C. Hand tighten
connections and then slightly tighten with an
adjustable wrench.
DRY CONNECTION ONLY.
NOTE: During winter month it may be necessary
to reverse Hot and Cold connections to obtain
warmer temperature range of water.
After connecting to supply lines, turn on the
water and activate the faucet with your hands,
checking for leaks. Adjust water temperature by
rotating the screw on the UCM to your required
temperature.
REPLACEMENT OF SENSOR MODULE
If the Faucet is mounted onto Deck, first take it
out with proper care to not damage the
connectors and the wires. Take out the Gasket
from under Base of Faucet. Take the screw
completely out of the back of faucet.
After screw has been removed from the unit, pull
up faucet body top. There are 2 O-Rings on the
shank and one around the lenses of Sensor
Module that should be replaced if damaged.