Installation

SPEAKMAN
®
400 Anchor Mill Rd. New Castle, DE 19720 Phone: 800-537-2107 Fax: 800-977-2747
01/13 Visit us on the web at www.speakmancompany.com 92-S-91XX-98XX-R3
4of 16
Under sink, place rubber wire guard (with notch
facing forward) and pass the wires through
notch. The wires should be inside channel of
rubber wire guard to prevent pinching when
tightening. Insert metal washer and tighten the
locknut to provide enough tension into the
rubber guard. While tightening make sure the
position of Faucet on top of counter is straight.
Again make sure that the wires are not pinched.
Install the solenoid by engaging the thread by
hand first and continuing to tighten with an
adjustable wrench (you will need to hold Faucet
on top to prevent rotation).
Do not overtighten and don’t use any sealant.
DRY CONNECTION ONLY.
Connect the two faucet wires with the solenoid
wires. The connectors are color coded. If you
have an AC/DC unit, there is an additional wire
with black connector coming from the top of
power module that needs to be connected to
the transformer provided.
(not shown)
If the option has an UCM (under counter mixer),
connect it to the inlet of the solenoid:
-first by hand and then using an adjustable
wrench (do not overtighten).
DRY CONNECTION ONLY.