Installation
SPEAKMAN
®
400 Anchor Mill Rd. New Castle, DE 19720 Phone: 800-537-2107 Fax: 800-977-2747
01/13 Visit us on the web at www.speakmancompany.com 92-S-91XX-98XX-R3
12of 16
ACM (above counter mixer) with MO (manual override) Installation
1. Install the MO and ACM as described above.
NOTE: In this case the ACM has an extra By-pass outlet: -in total 2 branches of mixed water.
2. There are two branches with mixed water: -one goes to Solenoid inlet, and the other goes to bottom of
MO.
3. Form the side of MO the by-pass hose goes to the upper side of Solenoid discharge for manually controlled
side
NOTE: For MO is used a Solenoid with a by-pass branch at its outlet.