Installation

S-5141-LD REPAIR PARTS
SPEAKMAN
®
RPG05-108759 METERING VALVE
RPG05-109171 AERATOR
RPG05-108879 MOUNTING HARDWARE
RPG05-108060 HANDLE INDICATORS
ITEM NO. PART NO. DESCRIPTION
S-5141-LD ROUGH-IN DIAGRAM
SPEAKMAN
®
DIMENSIONS SUBJECT TO CHANGE WITHOUT NOTICE.
27°
2
15
16
"
75mm
1
5
8
"
41mm
1
13
16
"
47mm
4
15
16
"
125mm
3
9
16
"
90mm
8
"
149mm
1"
MAX DECK THICKNESS
25mm
3
1
"
29mm
16
"
16
MIN DECK HOLE
24mm
15
5
7
4"
102mm
1/2"-14 NPSM THD
2
3
16
"
55mm
TIMING ADJUSTMENT 1
The spray timing is pre-adjusted at the factory. However, due to different field conditions, this adjustment may need to
be modified at the time of installation. Begin by removing the Screw (1) from the back side of the Cold Side of the
Faucet using the supplied Hex Wrench. Lift the Handle Assembly (2) to remove and place aside.
Remove the Cartridge Cap (3) and place aside. Repeat for Hot Side of the Faucet.
TIMING ADJUSTMENT 2
Using a Flat Tip Screwdriver, either thread in or out the end screw of the metering cartridge to adjust the duration of the
spray timing. IMPORTANT: Do NOT screw more than 1 complete rotation in either direction or damage may occur.
Replace the Cartidge Cap and Handle Assembly and press down on the handle to test spray duration. Once proper
timing is achieved on the Cold Side, replace the Screw to the back of the Faucet and tighten. Repeat for the Hot Side of
the Faucet.
¼ CLOCKWISE = INCREASE RUN TIME
¼ COUNTER CLOCKWISE = DECREASE RUN TIME