Installation Guide
SPEAKMAN COMPANY 
VS-117 Installation, Maintenance & Operation Instructions
VERSATILE ® VACUUM BREAKER 
DESCRIPTION 
VERSATILE® chrome plated brass in-line vacuum breaker. 
SPECIFICATIONS 
SUPPLY INLET: ½” NPSM FEMALE 
OUTLET : ½” NPSM MALE 
SHIPPING WEIGHT: XXX LBS. 
INSTALLATION 
Connect, using rubber washer, to supply piping. Connect accessories to vacuum breaker. Firmly hand tighten 
connection. Turn water supply on and check for leaks. 
Note: Do not install VS-117 in concealed locations or where spillage under certain service conditions might cause 
water damage. Avoid continuous pressure applications (shut off valve downstream of the vacuum breaker). 
MAINTENANCE 
The gleaming finish of your SPEAKMAN 
VERSATILE® VS-117 vacuum breaker can be 
cleaned by using mild soap and warm water. Dry 
immediately with a soft, clean cloth for best results.  
ROUGH-IN MEASUREMENTS
Product improvements may cause 
specification and dimensional 
changes without notice. 
SPEAKMAN COMPANY 
The Quality Leader Since 1869 
P.O. Box 191, Wilmington, DE 19899-0191 USA 
1-800-537-2107, Fax: 1-800-977-2747
04/00 