Specification
All dimensions are in inches (millimeters) unless otherwise specified and are subject to change without notice.
800-537-2107
800-977-2747
WWW.SPEAKMAN.COM
Architect/Engineer Approval Space:
P:
F:
W:
R:
Management Systems Registered to ISO 9001
SEF-1000
03-NOVEMBER 2019
Eyesaver® Laboratory Spout with Integrated Eyewash
SEF-1000 Spray Plume Length and Flow
Flowing Pressure
30 psi 40 psi 50 psi 60 psi 70 psi 80 psi
2.07 Bar 2.76 Bar 3.45 Bar 4.14 Bar 4.83 Bar 5.52 Bar
Flow Rate
1.9 gpm 2.1 gpm 2.2 gpm 2.1 gpm 2.2 gpm 2.3 gpm
7.2 L/min 7.9 L/min 8.3 L/min 7.9 L/min 8.3 L/min 8.7 L/min
Eyewash Distance
Plume ”A”
9.5” 10.5” 10.65” 10.5” 11” 11.5”
24.13 cm 26.67 cm 27.31 cm 26.67 cm 27.94 cm 29.21 cm
SEF-1000-8 Spray Plume Length and Flow
Flowing Pressure
30 psi 40 psi 50 psi 60 psi 70 psi 80 psi
2.07 Bar 2.76 Bar 3.45 Bar 4.14 Bar 4.83 Bar 5.52 Bar
Flow Rate
1.76 gpm 2.03 gpm 2.18 gpm 2.1 gpm 2.1 gpm 2.2 gpm
6.7 L/min 7.7 L/min 8.3 L/min 7.9 L/min 7.9 L/min 8.3 L/min
Eyewash Distance
Plume “A”
11.5” 13.0” 14.0” 13.0” 13.5” 13.75”
29.21 cm 33.02 cm 35.56 cm 33.02 cm 34.29 cm 34.93 cm
"A"
SEF-1000 SPRAY PLUME LENGTH AND FLOW
FLOWING PRESSURE
30 psi
2.07 Bar
40 psi
2.76 Bar
50 psi
3.45 Bar
60 psi
4.14 Bar
70 psi
4.83 Bar
80 psi
5.52 Bar
FLOW RATE
1.9 gpm
7.2 L/min
2.1 gpm
7.9 L/min
2.2 gpm
8.3 L/min
2.1 gpm
7.9 L/min
2.2 gpm
8.3 L/min
2.3 gpm
8.7 L/min
EYEWASH DISTANCE
PLUME "A"
9.5"
24.13cm
10.5"
26.67cm
10.65"
27.31cm
10.5"
26.67cm
11"
27.94cm
11.5"
29.21cm
6.606in
167.80mm
12.000°
2" [51mm]
MAX DECK THICKNESS
2.261in
57.42mm
5.252in
133.40mm
5.500in
139.71mm
6.625in
168.27mm
5.390in
136.91mm
3/8" COMPRESSION
(TYP)
HOT WATER INLET
3/8" COMPRESSION
COLD WATER INLET
3/8" COMPRESSION
TEPID WATER INLET
3/8" COMPRESSION
12°
8
5
8
"
219mm
70°
9
9
16
"
242mm
8"
203mm
7
1
4
"
184mm
2
1
4
"
57mm
7
7
8
"
200mm
2"
51mm
MAX DECK THICKNESS
HOT SUPPLY INLE
T
3/8" COMPRESSION
COLD SUPPLY INLET
3/8" COMPRESSION
3/8" COMPRESSION
(TYP)
TEPID WATER INLET
3/8" COMPRESSION
SEF-1000
SEF-1000-8
NOTE: If plume heights are low, check to ensure that your supply valves are fully open. If there is a
noticeable height dierence between the two plumes, remove the aerators and flow controls and
remove any debris that would inhibit the flow of water.