Installation Guide

4. Apply a thread sealant and attach shower head to 1" nipple on upper shower arm. Fasten lever
handle with screw located in extension. Secure pull rod to lever handle.
PLUMBING NOTES
1. The primary function of this unit is to keep water from freezing.
2. When possible, install unit in an area protected from direct blast of prevailing winter winds, to
minimize wind chill factor.
3. BE SURE WATER SUPPLY PIPING IS PROTECTED FROM FREEZING.
ELECTRICAL CONNECTION
1. Power supply requirement is 120 VAC, 60 cycle, single phase.
2. Ground-fault protection should be GFPD with a nominal 30 milliampere trip level to prevent
nuisance tripping.
3. Minimum 15 AMP breaker is required. (Breaker for shower only)
4. Use #14 AWG wire for power supply and make your hard wire connection inside the junction box.
Three (3) indicator wires * are supplied. You can throw these away once you have made your
connection.
*Indicator wires: 120 VAC, 60 cycles
Black wire: Hot
White wire: Common
Green wire: Ground