Specification
SPEAKMAN
400 ANCHOR MILL ROAD
NEW CASTLE, DE 19720
800-537-2107
800-977-2747
WWW.SPEAKMAN.COM
JANUARY 2016
Architect/Engineer Approval Space:
P:
F:
W:
R:
569
SE-362
FEATURES:
• 19 gpm @ 30 psi.
• Provides 8 gpm @ 30 psi cold water bypass in case
of hot water or thermostatic element failure
• Inlet connections: ¾ in. NPT
• Outlet connection: 1 in. NPT
• Temperature range: 65°-90° F
• Maximum pressure 125 PSI
• Inlet temperature hot: 120°-140° F
• Inlet temperature cold: 33°-80° F
• Minimum temperature Dierential
(from valve set point): 20° F
• Automatic spring check stops
• Valve holds to a +/- 3° F temperature
• Valves provide a positive shuto when cold water is
lost
• Integral strainer checkstops on inlets
• Set Point = 85°F
• Adjustable set point
• Lead Free
FINISH:
COMPLIANCE:
• ASSE 1071 Certified
• UPC (low lead) certified
OPTIONS:
Add sux to model #
• Flush mounted cabinet ❑ SE-366
WARRANTY:
• 1 year limited
• 10-Year warranty on thermostat
Thermostatic Mixing Valve
Rough Brass (standard)
FLOW CAPACITIES - GPM (L/MIN.)
MODEL MIN.
FLOW
PRESSURE DROP - PSI (BAR)
5
(.5)
10
(1.0)
15
(1.5)
20
(2.0)
30
(2.5)
45
(3.0)
60
(4.0)
SE-362 3.0
(11.5)
6.0
(29.0)
9.5
(46.0)
12.5
(60.0)
15.0
(72.0)
19.5
(83.5)
25.5
(96.5)
30.5
(113.5)
Minimum cold water bypass at 30 PSID (2bar): 8.0 GPM
This plumbing fixture is not intended to dispense water for human consumption through
drinking or for preparation of food or beverages.