Installation Guide
SPEAKMAN
®
400 Anchor Mill Rd. New Castle, DE 19720 Phone: 800-537-2107 Fax: 800-977-2747
8/17/17 www.speakman.com 92-SC-5811-01
OPERATION
Simply rotate the handles ¼ turn maximum to operate the sink fitting.
MAINTENANCE
Valves are washer less and require no routine maintenance. Your SPEAKMAN Commander sink fitting can be
cleaned by using mild soap and warm water. Dry immediately with a soft, clean cloth for best results.
ROUGH-IN
REPLACEMENT/REPAIR PARTS
ITEM PART/GROUP # DESCRIPTION
1 RPG04-0323-PC 4 Arm Handle Repair Group w/ Screw and Index Buttons
2 RPG05-0532 Perfect Valve Group (Red) w/ Trim Sleeve and Screw
3 RPG05-0533 Perfect Valve Group (Blue) w/ Trim Sleeve and Screw
4 RPG05-0520
Vacuum Breaker Repair Group w
/
Check Assembly, Hub,
Cap Screw, and O-Ring
5 RPG03-0361-RCP Integral Stop Spindle
6 RPG02-0141-PC Trim Collar for Valve