Installation Guide
3
Bench assemble the Tee to the HOT and COLD
end body valves. Be sure to fully seat the copper
piping into the end body valves, and hand
tighten Compression Nuts (1) to the outlet ports.
Be sure the end body valves are perpendicular
to the Tee assembly.
90°
4
Insert and position the Gooseneck Flange (1)
with Gasket (2) down through the center hole of
the sink or counter top, being sure the cut out of
the gasket is aligned to the rear of the faucet.
Assemble Rubber Washer (3), Metal Channel
Washer (4) and Mounting Nut (5) to shank and
thread only half way up the shank.
5
Loosen the Set Screws (1) and remove the end
body valve Flange Nuts (2) and Rubber Washers
(3). Screw the Locknuts (4) and Cup Washers (5)
down on end body valves.
6
From below the counter top, push the end body
with tee assembly up through the outer holes in
the sink or counter top.
NOTE: Blue colored end body (COLD) should
be on the right side of tee assembly, Red colored
end body (HOT) on the left. Hand tighten the tee
assembly’s Swivel Nut (2) to the Shank (1) of the
gooseneck flange.
BLUE
(COLD)
RED
(HOT)
7
While lifting the end body with tee assembly up
by its spindles, replace the Rubber Washers (1)
and screw the Flange Nuts (2) back onto the end
body valves, with flat side up, till they are flush
with the tops of the 1-1/8”-16 UN threads of the
end body valves.
8
Ensure the Flange Nuts (1)are flush with the tops
of the 1-1/8”-16 UN threads, then tighten Set
Screws (2).
9
From below, Wrench Tighten the Gooseneck
Flange Nut (1) with Channel Washer/Spacer (2),
Tee Swivel Nut (3), end body valve Locknuts (4)
with Cup Washers (5), and two (2) Tee
Compression Nuts (6) at the outlets of the end
body valves to secure the entire unit and prevent
leaks.
NOTE: Do Not Overtighten Swivel Nut
10
Connect water supply lines to inlets (1/2”-14
NPSM male threads) of the end body valves and
wrench tighten coupling nuts to prevent leaks.
NOTE: Flex Hoses and Shut Off Valves
not included.
1/2”-14 NPSM