DESCRIPTION
Speakman SENSORFLO faucet. Battery powered 4" centerset lavatory sensor faucet. Faucet
body consists of polished chrome plated removable cover and black powder coated chassis.
Sensor/electronic module powered by two (2) 3 Volt DC lithium batteries with waterproof
connectors housed above counter in the faucet body. Low battery warning light. New two
(2) inlet, one (1) outlet Solenoid design housed above counter in the faucet body. Hot and Cold
in-line filters housed above counter in the faucet body. Vandal resistant 60 second time out feature.
Water conserving vandal resistant recessed aerator reduces water flow to 0.5 GPM/ 1.9 LPM or
2.2 GPM/ 8.3 LPM to meet requirements of ASME A112.18.1/ CSA B125.1 standard for flow rates.
California AB1953 low lead compliant. ADA compliant. Note: 3/8" compression soft cone stainless
steel flexible hoses are optional.
SPECIFICATIONS
INLET SUPPLY: COUPLING OR 1 /2" SWEAT CONNECTION
FLOW RATE: 0.5 GPM/ 1.9 LPM OR 2.2 GPM/ 8.3 LPM
SHIPPING WEIGHT: 5.64 LBS
STATIC PRESSURE: 20-80 PSI
OPTIONS:
HS
2 Stainless Steel Flexible Hoses,
3/8" x 1/2" compression
HTS
1 Stainless Steel Flexible Hose
for Tempered Water Systems,
3/8" x 1/2" compression
LF
Vandal-Resistant 2.2 GPM Laminar
Flow Outlet
TMV
Under-Counter Thermostatic Mixing
Valve with Check Valves
VRS
Vandal-Resistant Screws with Wrench
INSTALLATION
If the highest allowable flow is required, remove the standard 0.5 GPM aerator and install the vandal
resistant 2.2 GPM aerator with the wrench provided. Carefully feed Inlets of faucet through deck
holes. Mount the faucet to fixture by fastening Cup Washers and Nuts to the inlet shanks (2). Ensure
gasket is properly seated on bottom of faucet chassis & wrench tighten shank nuts. Attach supplies
to inlet shanks using a compression coupling or 1/2" copper sweat connections. DRY CONNECTIONS
ONLY, DO NOT USE SEALANT. Remove cover from faucet body by unfastening the two (2) Allen
screws located in the front of the unit with the Allen wrench provided. Without loosening the Module
Fixing Plate, remove the electronic module cap by unfastening the Phillips Screw. After removing
the cap, install two lithium batteries, taking care to ensure correct polarity. Reassemble the module
cap. Set the tempered water temperature by adjusting the Temperature Adjusters to the Hot and
Cold water lines. Verify the faucet cover gasket is properly seated before placing cover back onto
the faucet body. Complete the closing of the faucet by refastening the two (2) Allen screws located
in the front of the unit. With drain installed, turn on water and activate the faucet, checking for
proper operation and all connections
for leaks.