Installation Guide

SPEAKMAN
®
400 Anchor Mill Rd. New Castle, DE 19720 Phone: 800-537-2107 Fax: 800-977-2747
11/30/15 www.speakman.com 92-S-8701-R4
SPEAKMAN
®
S-8701-CA, S-8701-CA-E
Installation, Maintenance & Operation Instructions
SENSORFLO® BATTERY POWERED LOW SPOUT LAVATORY FAUCET
DESCRIPTION
Speakman SENSORFLO® faucet. Battery powered low spout lavatory sensor faucet including under counter mixing valve
with built-in backflow check valves. All metal spout assembly consists of polished chrome plated removable cover and
black powder coated chassis. Sensor module powered by two (2) 3-volt DC lithium batteries with waterproof connectors
housed above counter in faucet body. Low battery warning light. Solenoid with built-in filter. Vandal resistant 60 second
time out feature. Water conserving vandal resistant recessed aerator reduces water flow to 1.5 GPM / 5.7 LPM or 0.5
GPM / 1.9 LPM (-E models)
to meet requirements of ANSI A112.18.1M for flow rates. ADA compliant. Note: 3/8’ Stainless Steel Hoses
are optional.
SPECIFICATIONS
INLET SUPPLY: 3/8” COMPRESSION WITH MALE THREADS
FLOW RATE: 1.5 GPM / 5.7 LPM or 0.5 GPM / 1.9 LPM (-E models)
SHIPPING WEIGHT: 4.5 LBS
Options:
E
Vandal Resistant 0.5 GPM Flow Control
LF
Vandal Resistant Laminar 2.2 GPM Flow Control
HS
2 Stainless Steel Hoses for use with Under
Counter Mixer
VRS
Vandal Resistant Screws with Wrench
INSTALLATION
Remove cover from faucet body. Disconnect sensor module wires and remove module from faucet. Remove battery cover
from module and install new batteries, taking care to ensure correct polarity. Reassemble in reverse order as above.
Make sure module wire is plugged in and clipped into place on top of the module. Wires should be on the inside of cover
screw bosses of chassis to prevent pinching. Reattach cover to faucet with screws and wrench provided. Install vandal
resistant aerator with wrench provided. Ensure gasket is properly seated on bottom of faucet chassis. Carefully feed wire
from faucet through deck hole, mounting faucet on fixture. Attach notched wire guard (notched end up) washer and lock
nut onto faucet shank and secure faucet to fixture. CAUTION: Sensor module wire must be inside channel of rubber wire
guard to keep wire from being pinched or cut when tightening washer and lock nut. Attach outlet of solenoid valve to
shank of faucet. Attach under counter mixing valve to inlet of solenoid, attach supplies to mixing valve using 3/8”
compression fittings. DRY CONNECTIONS ONLY. Connect wire from faucet to solenoid valve. With drain installed, turn
on water and activate the faucet, checking for proper operation and all connections for leaks. Once positive faucet is
operating properly adjust temperature of water delivered by rotating the adjusting screw (clockwise for more cold water)
on the mixer until the proper mix of hot and cold water is achieved.
OPERATION
Speakman SENSORFLO® faucets are thoughtfully designed for all in mind. Requires no handles to turn, lift
or push, water flows only when hands are in the lavatory basin. Built in vandal resistant circuitry shuts off
the water after continuous flow of approximately 60 seconds. This feature prevents flooding; water is easily turned on
again by placing one’s hands under the lavatory spout.
MAINTENANCE
Your SENSORFLO® faucet is designed and engineered in accordance with the highest quality and performance
standards. With proper care it will provide years of trouble free service. Periodically the faucet will require some minor
maintenance to keep it performing at peak performance. The sensor module has a built-in low battery indicator light
located in the center of the rectangle infrared lens. This red light will come on when the faucet has approximately 30,000
on/off cycles remaining or 10% of battery life. To replace the batteries follow the first portion of the installation instructions
above. Periodically check the solenoid filter