Installation Guide
6
Insert the Valve Assembly between the installed
Union Bodies. Thread Union Nuts onto Valve
Body and wrench tighten, being sure Shower
Arm Gooseneck is in a true vertical position.
Turn on water supply and check for leaks.
7
Install Wall Bracket to upper pipe using Supplied
Screws. Mounting location is optional. In drywall
or tile applications, be sure to use appropriate
hardware.
8
Thread included showerhead onto the Gooseneck
and wrench tighten.
NOTE: Showerhead may differ from illustration.
9
The Handle and Dial Cap must be removed to
adjust the Temperature Limit Stop. Remove the
Handle Screw (1), then slide the Handle (2) off.
Remove the Dial Cap Screw (3) followed by
sliding off the Dial Cap.
1
2
3
4
10
To limit the maximum hot water temperature the
valve delivers, adjust the valve’s temperature limit
stop (TLS) plate as shown below.
1) Slip the retaining O-ring and the TLS plate
towards the end of the spindle.
2) Rotate the valve spindle clockwise to the
maximum desired hot water temperature.
3) Positition the TLS plate so it contacts the lug on
the valve bonnet and therefore restricts the
clockwise rotation of the spindle.
4) Slip the retaining O-ring back into the groove
of the spindle to hold the TLS plate in position.
5) Rotate the spindle counter clockwise to the
“Off” positition.
O-RING
ROUGH-IN DIAGRAM
7
1
2
"
190.5mm
S-2252
Pipe Strap
W/ Screws
(Location
Optional)
Loose Key
Angle Stop
(2 Places)
Cold Inlet
Union
5"
127mm
6"
152.24mm
7
1
4
184.29mm
18
7
8
"
479.59mm
4'-6"
(1.37 meters)
To Floor
"
Hot Inlet
Union
1"
25.4mm
ADDITIONAL NOTES:
- Dimensions shown above are for the installation inclusive of the S-2252 showerhead. Dimensions will vary slightly
depending on showerhead choice.
- Dimensions are subject to change without notice.
- Unit can also be installed using a ceiling or floor supply.