Installation Sheet

3
Ensure that the water supplies are turned "OFF". Remove the OLD Cartridge Assembly by following Step 1. Make adjustments of the New Cartridge
Assembly Kit by following the Steps below.
• Gently take off Retaining Clip and TLS Plate .
• Using a Screwdriver, pop open the Bonnet . Pull out the Cartridge from the Transfer Part .
• Rotate the Cartridge 180˚ and reinstall into the Transfer Part . The “H” marking on the Cartridge cover should now be on the right hand side.
Snap the Bonnet back into the Transfer Part .
• Place the O-Ring as supplied with this Kit into the Valve Body Cavity.
• Install the reassembled Cartridge Assembly to the Valve Body using the four (4) Bonnet Screws from the existing Shower Valve.
• Install with the word "UP" facing upward .
• Reinstall the TLS Plate and Clip .
ROTATE
180˚
If you are performing this installation
with the following trims:
CPT-3000
CPT-3400
please use the
SPINDLE EXTENSION
and included
SCREW.
If you are performing a Back-to-Back
Installation, or have reversed inlet
supplies, please proceed to Step 3
4
Ensure the Valve is in the “OFF” position. Turn “ON” water supplies and check all connections
for leaks. Proceed to Step 5 for any temperature limit adjustment prior to reinstalling the Trim
(if any) accordingly.
BONNET LUG
TLS PLATE
CLIP
The maximum outlet temperature setting adjustment (Temperature Limit Stop (TLS)) of the Valve has been
factory set at 110° F. To adjust the limit of the maximum outlet temperature the Valve delivers, adjust
the Valve’s temperature limit stop (TLS) Plate.
• Slip the Retaining Clip away from the
Spindle and the TLS Plate towards the end of
the Spindle.
• With the water supplies “On”, rotate the
Valve Spindle clockwise to the maximum
desired outlet temperature.
• Position the TLS Plate so it contacts the Lug
on the Bonnet and therefore restricts the
clockwise rotation of the Spindle.
• Slip the Retaining Clip back into the groove
of the Spindle to hold the TLS plate in place.
• Rotate the Spindle counter-clockwise to the
“Off” position.
TEMPERATURE LIMIT ADJUSTMENT5
NOTE: A thermometer can be held at the Valve outlet to aid in either checking the existing factory setting
or reaching the desired outlet temperature.