Installation Sheet
INSTRUCTIONS FOR MODELS
92-CPT-3001-01
For additional assistance or service please contact:
SPEAKMAN
®
800-537-2107
customerservice@speakman.com
www.speakman.com
CPT-3001
CPT-3401
TOOLS AND SUPPLIES
IMPORTANT
Warranty information can be found at:
www.speakman.com
MAINTENANCE
WARRANTY
Phillips
Screwdriver
Hex Key Wrench
(included)
• Be sure to read instructions thoroughly before
beginning installation.
• Be sure to have properly adjusted the Temperature
Limiting Stop (TLS) as outlined in the Valve Installation
Manual.
• Cover your drain to prevent loss of parts. Be sure to
wear eye protection while cutting pipe.
Your new Valve Trim is designed for years of
trouble-free performance. Keep it looking new by
cleaning it periodically with a soft cloth. The use of
harsh chemicals and abrasives on any of the Speakman
custom finish products may damage the finish and void
the product warranty. Please be sure to only use
approved cleaners. Please contact Speakman for any
clarification of acceptable cleaners.
1
OPTIONAL: If a firm fit is required, insert the O-Ring ❶ onto the Bonnet ❷ of the Shower Valve.
2
Verify that the Valve is in the “OFF” position. Install the Wall Plate ❶ to the Valve. If installing a Diverter
model of Trim, align the Diverter Handle to the 12 o’clock position and position the Diverter Drive Tube ❷
over the Diverter Spindle of the Valve. Secure with the included Mounting Screws ❸.