Installation & Assembly
3
MEASURE
The Universal Valve Trim kit includes two Spindle Adapters that allow for both shallow and deep
valve mount installations. Measure the distance between the front lip of the Wall Mounting Plate
and the end of the Valve Spindle as shown below to determine correct selection of Spindle
Adapter.
• If the measurement falls between 1-7/8” to 2-1/2”, the Spline Adapter marked “A” is
needed for installation.
• If the measurement falls between 1-3/8” to 1-7/8”, the Spline Adapter marked “B” is
needed for installation.
A
B
4
VERTICAL
LINE
Confirm that the Valve is in the off position. Insert Spline Adapter (1) (Spline Adapter selection
determined in Step 3) over Valve Spindle (2). One set of splines on the adapter must be oriented
perfectly vertical when installed, as shown below. Secure the Spline Adapter with the 8-32 X 3/8”
Screw (3) provided.
5
RED
BLUE
Orient the Decorative Wall Plate (1) as shown below and insert the RED index button into the top
hole of the Wall Plate, and the BLUE index button into the lower hole. Slide Wall Plate Assembly
over Wall Mounting Plate (2).
6
Orient the Handle Assembly in a vertical position as shown below. Guide Handle Assembly onto
the Spline Adapter (3). While holding the Handle (1) stationary in the vertical position, thread the
Handle Escutcheon (2) onto the Wall Mounting Plate (4). Hand tighten until snug.
NOTE: This style of Valve uses a “Compression Stop”. After Handle Assembly
installation, rotate Handle clockwise to achieve full compression and closure of Valve.
If the Handle does not rest in a vertical position after full compression, repeat Steps 4
and 6 for proper Handle alignment.