User's Manual
Wireless Service Manual
Page 113 of 124 RA14-11A-022
Test ITEM (7)
Auto offset
Frequency
D: Daily ■ M: Monthly □
Q: Quarterly □ A: Annually □
Objective:
Check that Flat panel’s offset changes caused by the increased heat are automatically corrected.
Equipment:
Workstation, VXvue S/W
Power supply, Power Meter
Stop watch
Inspection Report Form
Procedure:
Turn on the power of the system.
Run VXSetup.
Set the period of offset or temperature change.
Run VXvue.
Performance and Corrective Action:
Check if Auto offset is set and performed when operating VXvue.
Check if Auto offset operates after the chosen time setting is over.
If offset is not set automatically and does not perform, ask for service assistance.
If the chosen time setting is exceeded, recheck the time setting.
If the image is not normal due to the dislocation of offset, send the image and ask for service assistance.
Record result on Inspection Report Form.
Result:
Frequency: D: □, M: □, Q: □, A: □ Date: 20**-**-** Operator:
Limit of Acceptability: N/A
Remarks: