User's Manual

Wireless Service Manual
Page 101 of 124 RA14-11A-022
5.4.5 Detector Preference
1 If you need to rotate the detector, select the value of Detector direction compensation.
2 To exclude the particular area of an image, select the desired area by clicking the Show Area button
after acquiring an image, or click the Select Area button after entering the size of image in the Effective
Area field.
3 To renew the automatic offset of the detector, check the Use offset refresh checkbox and set time
interval, temperature, the number of acquiring images.
Once the Use offset refresh checkbox is checked, the temperature of detector is
monitored at the time interval specified. If there is difference between the current
temperature and the specified one, images are acquired according to the number of
acquiring images which you have already set, and then the offset is renewed.
4 Click the Ruler button after acquiring an image, measure the length of it, and then enter the value.
5 Enter all the data you need, and then save the setting by clicking the Set button at the bottom.