- Chapter 1: Getting Started
- Chapter 2: System Setup
- Displaying the setup pages
- Restoring default settings
- A & B Key, Footswitch setup
- Administration setup
- Annotations setup
- Audio, Battery setup
- Cardiac Calculations setup
- Connectivity setup
- Date and Time setup
- Display Information setup
- IMT Calculations setup
- Network Status setup
- OB Calculations setup
- OB Custom Measurements setup
- OB Custom Tables setup
- Presets setup
- System Information setup
- USB Devices setup
- Chapter 3: Imaging
- Chapter 4: Measurements and Calculations
- Chapter 5: Troubleshooting and Maintenance
- Chapter 6: Safety
- Ergonomic safety
- Electrical safety classification
- Electrical safety
- Equipment safety
- Battery safety
- Clinical safety
- Hazardous materials
- Electromagnetic compatibility
- ALARA principle
- Acoustic artifacts
- Guidelines for reducing MI and TI
- Output display
- Transducer surface temperature rise
- Acoustic output measurement
- Acoustic output tables
- Labeling symbols
- Chapter 7: References
- Chapter 8: Specifications
- Glossary
- Index
Chapter 4: Measurements and Calculations 67
Measurements
2 OnafrozenDopplerspectraltrace,pressthe
CALCSkey.
3 Fromthecalculationsmenu,selectLeftor
Right.
4 Dothefollowingforeachmeasurementyou
wanttotake:
a Fromthecalculationsmenu,selectthe
measurement.(Youmayneedtoselect
NextorPrevtolocatethemeasurement.)
b Dooneofthefollowing:
•Foramanualtracemeasurement,usethe
touchpadtopositionthecaliper.Pressthe
SELECTkey.Usethetouchpadtotracethe
waveform.
Ifyouneedtomakeacorrection,select
Undoon‐screenorpressthe
BACKSPACE
key.
•Foranautotracemeasurement,select
Autoon‐screen,andusethetouchpadto
positionthefirstcaliperatthebeginning
ofthewaveform.Pressthe
SELECTkey,and
positionthesecondcaliperattheendof
thewaveform.
Confirmthatthesystem‐generated
boundaryiscorrect.Ifyouarenotsatisfied
withthetrace,obtainahigherquality
Dopplerspectraltraceimage,ortrace
manually.
c Pressthe
SETkey.
d Savethecalculation.(See“Tosavea
calculation”onpage 45.)
Vascular calculations
Thevascularmeasurementsthatyoucansaveto
thepatientreportarelistedinthefollowingtable.
Fordefinitionsofacronyms,see“Glossary”on
page 157
WARNING:
To avoid misdiagnosis or harming
the patient outcome, start a new
patient information form before
starting a new patient exam and
performing calculations. Starting a
new patient information form
clears the previous patient’s data.
The previous patient’s data will be
combined with the current patient
if the form is not first cleared. See
“To create a new patient
information form” on page 34.
To avoid incorrect calculations,
verify that the patient information,
date, and time settings are
accurate.
Transducer Exam Type
C11x Vascular
HFL38x Vascular
L25x Vascular
L38x Vascular
SLAx Vascular