User's Manual
Table Of Contents
- M-Turbo Ultrasound System User Guide
- Contents
- Introduction
- Chapter 1: Getting Started
- Chapter 2: System Setup
- Displaying the setup pages
- Restoring default settings
- A & B Key, Footswitch setup
- Administration setup
- Annotations setup
- Audio, Battery setup
- Cardiac Calculations setup
- Connectivity setup
- Date and Time setup
- Display Information setup
- IMT Calculations setup
- Network Status setup
- OB Calculations setup
- OB Custom Measurements setup
- OB Custom Tables setup
- Presets setup
- System Information setup
- USB Devices setup
- Chapter 3: Imaging
- Chapter 4: Measurements and Calculations
- Chapter 5: Troubleshooting and Maintenance
- Chapter 6: Safety
- Ergonomic safety
- Electrical safety classification
- Electrical safety
- Equipment safety
- Battery safety
- Clinical safety
- Hazardous materials
- Electromagnetic compatibility
- ALARA principle
- Acoustic artifacts
- Guidelines for reducing MI and TI
- Output display
- Transducer surface temperature rise
- Acoustic output measurement
- Acoustic output tables
- Labeling symbols
- Chapter 7: References
- Chapter 8: Specifications
- Glossary
- Index
32 Annotating images
Annotating images
Youcanannotateliveimagesaswellasfrozen
images.(Youcannotannotateasavedimage.)
Youcanplacetext(includingpredefinedlabels),
anarrow, orapictograph.Tosetpreferencesfor
annotations,see“Annotationssetup”onpage 18.
To place text on an image
Youcanplacetextinthefollowingimaging
layouts:full‐screen2D,full‐screentrace,dual,or
duplex.Youcanplacetextmanuallyoradda
predefinedlabel.
1 Pressthe
TEXTkey.Agreencursorappears.
2 Movethecursorwheredesired:
•Usethetouchpadorarrowkeys.
•SelectHometomovethecursortothe
homeposition.
L25x Msk
XXXX—
Vas
XXXX—
Nrv
XXXX—
Oph
XXXX—
Sup
XXXX—
Ven
XXXX—
L38x Bre
XXXX—
SmP
XXXX—
Vas
XXXX—
IMT
XXXX—
Nrv
XXXX—
Ven
XXXX—
P10x Abd
XXXX—
Crd
X—XX X
Neo
XXXX—
P21x Abd
XXXX—
OB
XXXX—
Crd
X—XX X
TCD
XXXX—
Orb
XXXX—
SLAx Msk
XXXX—
Nrv
XXXX—
Sup
XXXX—
Imaging Mode
Transducer
Exam Type
1
2D
2
M Mode
CPD
3
Color
3
PW Doppler
4
CW Doppler
Vas
XXXX—
Ven
XXXX—
TEEx Crd
X—XX X
1. Exam type abbreviations are as follows: Abd = Abdomen,
Bre = Breast, Crd = Cardiac, Gyn = Gynecology, IMT =
Intima Media Thickness, Msk = Muscle, Neo = Neonatal,
Nrv = Nerve, OB = Obstetrical, Oph = Ophthalmic, Orb =
Orbital, SmP = Small Parts, Sup = Superficial, TCD =
Transcranial Doppler, Vas = Vascular, Ven = Venous.
2. The optimization settings for 2D are Res, Gen, and Pen.
3. The optimization settings for CPD and Color are low,
medium, and high (flow sensitivity) with a range of PRF
settings for Color depending on the setting selected.
4. For the cardiac exam type, PW TDI is also available. See
“PW Doppler options” on page 29.
Imaging Mode
Transducer
Exam Type
1
2D
2
M Mode
CPD
3
Color
3
PW Doppler
4
CW Doppler