User's Manual
Table Of Contents
- M-Turbo Ultrasound System User Guide
- Contents
- Introduction
- Chapter 1: Getting Started
- Chapter 2: System Setup
- Displaying the setup pages
- Restoring default settings
- A & B Key, Footswitch setup
- Administration setup
- Annotations setup
- Audio, Battery setup
- Cardiac Calculations setup
- Connectivity setup
- Date and Time setup
- Display Information setup
- IMT Calculations setup
- Network Status setup
- OB Calculations setup
- OB Custom Measurements setup
- OB Custom Tables setup
- Presets setup
- System Information setup
- USB Devices setup
- Chapter 3: Imaging
- Chapter 4: Measurements and Calculations
- Chapter 5: Troubleshooting and Maintenance
- Chapter 6: Safety
- Ergonomic safety
- Electrical safety classification
- Electrical safety
- Equipment safety
- Battery safety
- Clinical safety
- Hazardous materials
- Electromagnetic compatibility
- ALARA principle
- Acoustic artifacts
- Guidelines for reducing MI and TI
- Output display
- Transducer surface temperature rise
- Acoustic output measurement
- Acoustic output tables
- Labeling symbols
- Chapter 7: References
- Chapter 8: Specifications
- Glossary
- Index
Chapter 3: Imaging 31
Imaging
down,left,andright.(Youcannotpanin
Dual.)
Toexitzoom,pressthe
ZOOMkeyagain.
Imaging modes and exams
available by transducer
Thetransduceryouusedetermineswhichexam
typesareavailable.Inaddition,theexamtype
youselectdetermineswhichimagingmodesare
available.
To change the exam type
Dooneofthefollowing:
•Pressthe
EXAMkey,andselectfromthe
menu.
•Onthepatientinformationform,select
fromtheTypelistunderExam.(See
“Patientinformationform”onpage 33.)
Imaging modes and exams available by
transducer
WARNING:
To prevent misdiagnosis or harm to
the patient, understand your
system’s capabilities prior to use.
The diagnostic capability differs for
each transducer, exam type, and
imaging mode. In addition,
transducers have been developed
to specific criteria depending on
their physical application. These
criteria include biocompatibility
requirements.
To avoid injury to the patient, use
only an Orbital (Orb) or Ophthalmic
(Oph) when performing imaging
through the eye. The FDA has
established lower acoustic energy
limits for ophthalmic use. The
system will not exceed these limits
only if the Orb or Oph exam type is
selected.
Imaging Mode
Transducer
Exam Type
1
2D
2
M Mode
CPD
3
Color
3
PW Doppler
4
CW Doppler
C11x Abd
XXXX—
Neo
XXXX—
Nrv
XXXX—
Vas
XXXX—
C60x OB
XXXX—
Gyn
XXXX—
Abd
XXXX—
Nrv
XXXX—
D2x Crd
———— X
HFL38x Bre
XXXX—
SmP
XXXX—
Vas
XXXX—
Msk
XXXX—
IMT
XXXX—
Nrv
XXXX—
Ven
XXXX—
ICTx Gyn
XXXX—
OB
XXXX—