Data Sheet

RN-42/RN-42-N Data Sheet
www.rovingnetworks.com DS-RN42-V3.2 6/21/2011
809 University Avenue Los Gatos, CA 95032 Tel (408) 395-6539 info@RovingNetworks.com
~ 2 ~
Overview
Baud rate speeds: 1200bps up to 921Kbps, non-standard baud rates can be programmed.
Class 2 radio, 60 feet (20meters) distance, 4dBm output transmitter, -80dBm typical receive sensitivity
Frequency 2402 ~ 2480MHz,
FHSS/GFSK modulation, 79 channels at 1MHz intervals
Secure communications, 128 bit encryption
Error correction for guaranteed packet delivery
UART local and over-the-air RF configuration
Auto-discovery/pairing requires no software configuration (instant cable replacement).
Auto-connect master, IO pin (DTR) and character based trigger modes
Digital I/O Characteristics
2.7V ≤ VDD ≤ 3.0V
Min
Typ.
Max.
Unit
Input logic level LOW
-0.4
-
+0.8
V
Input logic level HIGH
0.7VDD
-
VDD+0.4
V
Output logc level LOW
-
-
0.2
V
Output logic level HIGH
VDD-0.2
-
-
V
All I/O’s (except reset) default to weakpull down
+0.2
+1.0
+5.0
uA
Environmental Conditions
Parameter
Value
Temperature Range (Operating)
-40
o
C ~ 85
o
C
Temperature Range (Storage)
-40
o
C ~ 85
o
C
Relative Humidity (Operating)
90%
Relative Humidity (Storage)
90%
Electrical Characteristics
Min
Typ.
Max.
Unit
3.0
3.3
3.6
V
40
mA
25
mA
12
mA
40
45
50
mA
26
uA
* If in SLAVE mode there are bursts of radio ON time which vary with the windows. Depending on how you set
the windows that determines your average current.