Data Sheet
DocID031281 Rev 2 15/35
VL53L1X Ranging performances
35
3 Ranging performances
3.1 Test conditions
In all measurement tables of this specification, it is considered that:
1. The full FoV (typically 27 °) is covered or a partial FoV is covered after a specific ROI is
programmed by the user (array size from 4x4 SPADs to 16x16 SPADs).
2. Charts used as targets are: grey 17 % reflectance (N4.74 Munsell), grey 54 %
reflectance (N8.25 Munsell), and white 88 % reflectance (N9.5 Munsell).
3. Nominal voltage (2.8 V) and temperature (23 °C).
4. Detection rate is considered as 100 %.
5. Unless mentioned, the device is setup and controlled through the driver using the
following settings:
a) Distance mode is long
b) Timing budget is 100 ms
c) No cover glass is present
d) Target covers the full FoV
6. Ambient light is defined as follows:
a) Dark = no IR light in the band 940 nm ±30 nm
b) 50 kcps/SPAD = lighting on a sunny day from behind a window
(a)
c) 200 kcps/SPAD = lighting on a sunny day from behind a window, with direct
illumination on the sensor
d) For reference, usual office lighting is around 5 kcps/SPAD
a. kcps is kilo counts per second. kcps/SPAD is the return ambient rate measured by the VL53L1X.