Data Sheet

Page 68
RFM69HCW
Tel: + 86-755-82973805 Fax: +86- 755-82973550 E-mail: sales@hoperf.com http:/ / www.hoperf.com
ADVANCED COMMUNICATIONS & SENSING DATASHEET
7-6 OokThreshType rw 01 Selects type of threshold in the OOK data slicer:
00 fixed 10 average
01 peak 11 reserved
5-3 OokPeakTheshStep rw 000 Size of each decrement of the RSSI threshold in the OOK
demodulator:
000 0.5 dB 001 1.0 dB
010 1.5 dB 011 2.0 dB
100 3.0 dB 101 4.0 dB
110 5.0 dB 111 6.0 dB
RegOokPeak
(0x1B)
2-0 OokPeakThreshDec rw 000 Period of decrement of the RSSI threshold in the OOK
demodulator:
000 once per chip 001 once every 2 chips
010 once every 4 chips 011 once every 8 chips
100 twice in each chip 101 4 times in each chip
110 8 times in each chip 111 16 times in each chi
p
7-6 OokAverageThreshFilt rw 10 Filter coefficients in average mode of the OOK
demodulator:
00 f
C
chip rate / 32.π 01 f
C
chip rate / 8.π
10 f
C
chip rate / 4.π 11 f
C
chip rate / 2.π
RegOokAvg
(0x1C)
5-0 - r 000000 unused
RegOokFix
(0x1D)
7-0 OokFixedThresh rw 0110
(6dB)
Fixed threshold value (in dB) in the OOK demodulator.
Used when OokThresType = 00
7 - r 0 unused
6 FeiDone r 0 0 FEI is on-going
1 FEI finished
5 FeiStart w 0 Triggers a FEI measurement when set. Always reads 0.
4 AfcDone r 1 0 AFC is on-going
1 AFC has finished
3 AfcAutoclearOn rw 0 Only valid if AfcAutoOn is set
0 AFC register is not cleared before a new AFC phase
1 AFC register is cleared before a new AFC phase
2 AfcAutoOn rw 0 0 AFC is performed each time AfcStart is set
1 AFC is performed each time Rx mode is entered
1 AfcClear w 0 Clears the AfcValue if set in Rx mode. Always reads 0
RegAfcFei
(0x1E)
0 AfcStart w 0 Triggers an AFC when set. Always reads 0.
RegAfcMsb
(0x1F)
7-0 AfcValue(15:8) r 0x00 MSB of the AfcValue, 2’s complement format
RegAfcLsb
(0x20)
7-0 AfcValue(7:0) r 0x00 LSB of the AfcValue, 2’s complement format
Frequency correction = AfcValue x Fstep
RegFeiMsb
(0x21)
7-0 FeiValue(15:8) r - MSB of the measured frequency offset, 2’s complement
RegFeiLsb
(0x22)
7-0 FeiValue(7:0) r - LSB of the measured frequency offset, 2’s complement
Frequency error = FeiValue x Fstep
7-2 - r 000000 unused
1 RssiDone r 1 0 RSSI is on-going
1 RSSI sampling is finished, result available
RegRssiConfig
(0x23)
0 RssiStart w 0 Trigger a RSSI measurement when set. Always reads 0.
RegRssiValue
(0x24)
7-0 RssiValue r 0xFF Absolute value of the RSSI in dBm, 0.5dB steps.
RSSI = -RssiValue/2 [dBm]