Data Sheet
[AK9753]
017005237-E-00 2017/04
- 35 -
8). TMPL, TMPH: Measurement Data of the Integrated temperature Sensor (Read / Write Registers)
Address
Name
D7
D6
D5
D4
D3
D2
D1
D0
0EH
TMPL
TMPL_7
TMPL_6
TMPL_5
TMPL_4
TMPL_3
TMPL_2
TMPL_1
TMPL_0
0FH
TMPH
TMPH_15
TMPH_14
TMPH_13
TMPH_12
TMPH_11
TMPH_10
TMPH_9
TMPH_8
Reset
0
0
0
0
0
0
0
0
Note:
* 15. TMPL_0 bit to TMPL_5 bit are fixed to “0”.
Measurement Data of the Integrated Temperature Sensor
TMPL [7:0]: Least significant 8-bits in output data
TMPH [15:8]: Most significant 8-bits in output data
16-bit data is stored in two’s compliment format.
Table 14.3. Measurement Data of the Integrated Temperature Sensor
Measurement Data of the Integrated Temperature Sensor [15:0]
Temperature
Unit
Two’s Complement
Hex
Decimal
0100 0011 1000 0000
4380
17792
60
ºC
⁞
⁞
⁞
⁞
0000 0001 0000 0000
0100
256
26.75+0.5
⁞
⁞
⁞
⁞
0000 0000 0100 0000
0040
64
26.75+0.125
0000 0000 0000 0000
0000
0
26.75
1111 1111 1100 0000
FFC0
-64
26.75-0.125
⁞
⁞
⁞
⁞
1111 1111 0000 0000
FF00
-256
26.75-0.5
⁞
⁞
⁞
⁞
1011 1001 1000 0000
B980
-18048
-10
The Resolution of the Integrated Temperature Sensor
Table 14.4. The Resolution of the Integrated Temperature Sensor
EFC[2:0] Setting
EFC= All Setting
Resolution
10-bit (0.125ºC)
9). ST2: Status 2 (Read Only Registers)
Address
Name
D7
D6
D5
D4
D3
D2
D1
D0
10H
ST2
Reset
1
1
1
1
1
1
1
1
Note:
* 16. ST2 register is the dummy data register for the measured data reading routine.ST2 register MUST
be read after reading out the measured data.