Data Sheet
Page 83
RFM95/96/97/98(W)
Tel: + 86-755-82973805 Fax: +86- 755-82973550 E-mail: sales@hoperf.com http:/ / www.hoperf.com
WIRELESS & SENSING PRELIMINARY DATASHEET
01b / 20 6 6.3
00b / 16 6 7.8
10b / 24 5 10.4
01b / 20 5 12.5
00b / 16 5 15.6
10b / 24 4 20.8
01b / 20 4 25.0
00b / 16 4 31.3
10b / 24 3 41.7
01b / 20 3 50.0
00b / 16 3 62.5
10b / 24 2 83.3
01b / 20 2 100.0
00b / 16 2 125.0
10b / 24 1 166.7
01b / 20 1 200.0
00b / 16 1 250.0
Other settings reserved
5.5.7. Temperature Measurement
A stand alone temperature measurement block is used in order to measure the temperature in any mode except Sleep and
Standby. It is enabled by default, and can be stopped by setting TempMonitorOff to 1. The result of the measurement is
stored in TempValue in RegTemp.
Due to process variations, the absolute accuracy of the result is +/- 10 °C. Higher precision requires a calibration procedure
at a known temperature. The figure below shows the influence of just such a calibration process. For more information,
including source code, please consult the applications Section of this document.
Figure 41. Temperature Sensor Response