Data Sheet

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
Infrared Array Sensor Grid-EYE (AMG88)
10 kΩ±5%
10 kΩ±5%
20 Ω±5%
10 µF±20%
1.5 µF±10%
1 µF±10%
10 kΩ±5%
GND
VDD
To microcomputer etc.
To microcomputer etc.
To microcomputer etc.
2SDA
3SCL
4INT
5
AD_SELECT
6GND
MVPP
LDVDD-PC
JAVDD-PC
9VDD
1.5 dia.
+0.1
0
0.059 dia.
+0.004
0
9.0±0.1
2.0±0.1
4.0±0.1
0.079±0.004
0.157±0.004
16.0±0.1
0.630±0.004
12.6±0.1
0.496±0.004
Direction of picking
16.0±0.3
7.5±0.1
1.75±0.1
0.630±0.012
0.295±0.004 0.069±0.004
1.5
dia.
+0.1
0
0.059
dia.
+0.004
0
0.35±0.05
0.014±0.020
4.7
±0.1
0.354±0.004
0.185±0.004
10 kΩ±5%
10 kΩ±5%
10 kΩ±5%
20 Ω±5%
10 µF±20%
1.5 µF±10%
1 µF±10%
10 kΩ±5%
2SDA MVPP
LDVDD-PC
JAVDD-PC
9VDD
3SCL
4INT
5
AD_SELECT
6GND
GND
VDD
To microcomputer etc.
To microcomputer etc.
To microcomputer etc.
380.0±2.0 dia.
14.961±0.079 dia.
80±0.1 dia.
3.150±.039 dia.
Top cover tape
Embossed carrier tape
21.5±1.0
17.5±1.0
13±0.2 dia.
0.512±0.08 dia.
0.689±0.039
0.846±0.039
Precaution for fundamental structure of sensor
Infrared Array Sensor is a thermopile type infrared
sensor which detects the amount of infrared rays. Below
conditions generally degrade the temperature accuracy.
Carefully check the performance and stability under
actual use conditions, and perform temperature
corrections when necessary.
When heating elements exist near the mounting
position of the sensor.
When the sensor is exposed to cold or hot air.
When the temperature of the sensor body rapidly
changes.
When substances (e.g., glasses, acrylics or steams),
which hardly transmit a far infrared ray, exist
between the sensor and the detected object.
When substances (e.g., foreign substances or
water), which hardly transmit a far infrared ray,
adhere to the lense of the sensor.
Use environment
1) Temperature: See the specifications
2) Humidity: Between 15% and 85% R.H. (Avoid
freezing and dew condensation)
3) Atmospheric pressure: Between 86 and 106 kPa
4) Vibrations and shocks may damage the sensor, and
cause malfunction and performance deterioration.
If loads and shocks are applied on the lense,
the damaged sensor may cause malfunction and
performance deterioration.
5) The product is not water/splash-proof. Perform
water/dust-proofing and dew condensation/
freezing countermeasures in accordance with use
environment. When dew condensation occurs,
responsiveness of heat source detection may delay
for several seconds.
6) Avoid use and storage in the corrosive gas (organic
solvent, sulfurous acid and hydrogen sulfide gases)
to avoid malfunction and performance deterioration.
7) Use surge absorbers as applying the external surge
voltage may damage the internal circuit.
8) Malfunction may occur near electric noises from
static electricity, lightning, broadcast or amateur radio
stations and mobile phones.
9) The sensor can continuously operate within the
range of using ambient temperature (using ambient
humidity). However, ensure that humidity is within the
range described in the following page as humidity
varies according to temperature. Avoid the continuous
operation near the operational limit. The temperature
range does not guarantee the durability.
External circuit
(1)
In case of setting I
2
C slave address of the sensor 1101000
Connect terminal 5 (AD_SELECT) to GND.
This circuit is an example to drive infrared array sensor “Grid-EYE”, so that we will not take any responsibility of loss
which is due to this circuit.
(2)
In case of setting I
2
C slave address of the sensor 1101001
Connect terminal 5 (AD_SELECT) to VDD.
Tape dimensions Dimensions of tape reel
Packing format (Tape and reel)
unit : mm inch
Notes
Apr. 201702