Data Sheet

Page 9
BST-BME280-DS001-10 | Revision 1.1 | May 2015 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to
third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
100
80
60
20
0
40
Relative humidity [%]
Temperature [°C]
-40 -20 0 20 40 60 80
Figure 1: humidity sensor operating range
1.6 Pressure sensor specification
Table 3: Pressure parameter specification
Parameter
Symbol
Condition
Min
Typ
Max
Unit
Operating temperature
range
T
A
operational
-40
25
+85
°C
full accuracy
0
+65
Operating pressure
range
P
full accuracy
300
1100
hPa
Supply current
I
DD,LP
1 Hz forced mode,
pressure and
temperature, lowest
power
2.8
4.2
µA
Temperature coefficient
of offset
7
TCO
P
65 °C, 900 hPa
±1.5
Pa/K
±12.6
cm/K
Absolute accuracy
pressure
A
P,full
300 . . . 1100 hPa
0 . . . 65 °C
±1.0
hPa
Relative accuracy
pressure
V
DD
= 3.3V
A
rel

25 . . . 40 °C
±0.12
hPa
7
When changing temperature by e.g. 10 °C at constant pressure / altitude, the measured
pressure / altitude will change by (10 × TCO
P
).