Data Sheet
Final Datasheet
BME280 Environmental sensor
Page 7
BST-BME280-DS001-10 | Revision 1.1 | May 2015 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to
third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
1. Specification
If not stated otherwise,
All values are valid over the full voltage range
All minimum/maximum values are given for the full accuracy temperature range
Minimum/maximum values of drifts, offsets and temperature coefficients are ±3 values
over lifetime
Typical values of currents and state machine timings are determined at 25 °C
Minimum/maximum values of currents are determined using corner lots over complete
temperature range
Minimum/maximum values of state machine timings are determined using corner lots
°C temperature range
The specification tables are split into humidity, pressure, and temperature part of BME280.
1.1 General electrical specification
Table 1: Electrical parameter specification
Parameter
Symbol
Condition
Min
Typ
Max
Unit
Supply Voltage
Internal Domains
V
DD
ripple max. 50 mVpp
1.71
1.8
3.6
V
Supply Voltage
I/O Domain
V
DDIO
1.2
1.8
3.6
V
Sleep current
I
DDSL
0.1
0.3
µA
Standby current
(inactive period of
normal mode)
I
DDSB
0.2
0.5
µA
Current during
humidity
measurement
I
DDH
Max value at 85 °C
340
µA
Current during
pressure
measurement
I
DDP
Max value at -40 °C
714
µA
Current during
temperature
measurement
I
DDT
Max value at 85 °C
350
µA
Start-up time
t
startup
Time to first
communication after
both V
DD
> 1.58 V
and V
DDIO
> 0.65 V
2
ms
Power supply
rejection ratio (DC)
PSRR
full V
DD
range
±0.01
±5
%RH/V
Pa/V
Standby time
accuracy
Δt
standby
±5
±25
%