Data Sheet

Page 28
BST-BME280-DS001-10 | Revision 1.1 | May 2015 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to
third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
Table 26: Register 0xF5 config
Register 0xF5
“config”
Name
Description
Bit 7, 6, 5
t_sb[2:0]
Controls inactive duration t
standby
in normal mode. See
Table 27 for settings and chapter 3.3.4 for details.
Bit 4, 3, 2
filter[2:0]
Controls the time constant of the IIR filter. See Table 27
for settings and chapter 3.4.4 for details.
Bit 0
spi3w_en[0]
Enables 3-See
chapter 6.3 for details.
Table 27: t_sb settings
t_sb[2:0]
t
standby
[ms]
000
0.5
001
62.5
010
125
011
250
100
500
101
1000
110
10
111
20
Table 28: filter settings
filter[2:0]
Filter coefficient
000
Filter off
001
2
010
4
011
8
100, others
16
5.4.7 Register 0xF7…0xF9 “press” (_msb, _lsb, _xlsb)
The press register contains the raw pressure measurement output data up[19:0]. For details
on how to read out the pressure and temperature information from the device, please consult
chapter 4.