Data Sheet

ams Datasheet Page 5
[v1-00] 2016-Dec-23 Document Feedback
CCS811 − Absolute Maximum Ratings
Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. These are stress
ratings only. Functional operation of the device at these or any
other conditions beyond those indicated under Electrical
Characteristics is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device
reliability
Figure 5:
Absolute Maximum Ratings
Note(s):
1. The supply voltage V
DD
is sampled during boot and should not vary during operation.
2. The minimum supply voltage V
DD
is 1.8V and should not drop below this value for reliable device operation.
Symbol Parameter Min Max Units Comments
Electrical Parameters
V
DD
(1)
Supply Voltage
1.8
(2)
3.6 V
I
DD
Supply Current 30 mA In mode 1
P Power Consumption 60 mW In mode 1
Electrostatic Discharge
ESD
HBM
Human Body Model ±2000 V
Environmental Conditions
T
AMB
Ambient Temperature for Operation -5 50
o
C
T
STRG
Storage Temperature -40 125
o
C
RH
NC
Relative Humidity (non-condensing) 10 95 %
MSL Moisture Sensitivity Level 1
Unlimited max.
floor life time
Absolute Maximum Ratings