Data Sheet
RFD77402 DATASHEET v1.8
© 2017 RF Digital Corporation 7.24.2017
www.simblee.com
32
Simblee™ RFD77402
4.2 Maximum Ranging Distance and Ranging Accuracy
Table 29 below shows the ranging accuracy specifications of the device. The data for these measurements were
obtained with the device operating at room temperature and there was no cover glass on the device when the
measurements were performed.
Table 29: Range Accuracy Information in the Range of 50mm to 2000mm
(*) note that RFD77402’s official technical specification states ±10% accuracy in the range of 100mm to 2000mm