Datasheet

9.6 Handling and storage precautions
9.6.1 Shock precaution
Sensor modules house numerous internal components that are susceptible to shock damage. If a unit is subject
to excessive shock, is dropped on the floor, or a tray/reel of units is dropped on the floor, it must be rejected, even
if no apparent damage is visible.
9.6.2 Part handling
Handling must be done with non-marring ESD safe carbon, plastic, or teflon tweezers. Ranging modules are
susceptible to damage or contamination. The customer is advised to use a clean assembly process after
removing the tape from the parts, and until a protective cover glass is mounted.
9.6.3 Compression force
A maximum compressive load of 25 N should be applied on the module.
9.6.4 Moisture sensitivity level
Moisture sensitivity is level 3 (MSL) as described in IPC/JEDEC JSTD-020-C.
9.7 Storage temperature conditions
Table 18. Recommended storage conditions
Parameter Min. Typ. Max. Unit
Temperature (storage) -40 23 85 °C
VL53L4CD
Handling and storage precautions
DS13812 - Rev 3
page 30/36