Datasheet

5.4 Ranging accuracy
The figure below illustrates how range accuracy is defined over distance.
Figure 16. Ranging accuracy vs. distance
The ranging accuracy is a direct evaluation of the measurement error, including offset errors and output noise.
At least 90% of the ranging values are within the declared ranges. This quality indicator includes measure-to-
measure and part-to-part dispersion.
Table 15. Typical ranging accuracy with 33 ms timing budget
Target reflectance level, full
FoV
Distance (mm) Indoor (no infrared) Outdoor overcast
White target (88%)
1-100 ± 7 mm ± 8 mm
101-200 ± 8 mm ± 9 mm
>200 ± 3% ± 8%
Gray target (17%)
1-100 ± 6 mm ± 7 mm
101-200 ± 8 mm ± 9 mm
>200 ± 4% ± 8%
VL53L4CD
Ranging accuracy
DS13812 - Rev 3
page 19/36