Datasheet

4 Electrical characteristics
4.1 Absolute maximum ratings
Warning:
Stresses above those listed in the following table may cause permanent damage to the device.
This is a stress rating only and functional operation of the device at these or any other conditions
above those indicated in the operational sections of the specification is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
Table 9. Absolute maximum ratings
Parameter Min. Typ. Max. Unit
AVDD
-0.5 - 3.6 V
SCL, SDA, XSHUT and GPIO1
4.2 Recommended operating conditions
There are no power supply sequencing requirements. The I/Os may be high, low or floating when AVDD is
applied. The I/Os are internally failsafe with no diode connecting them to AVDD.
Table 10. Recommended operating conditions
There are no power supply sequencing requirements. The I/Os may be high, low or floating when AVDD is applied. The I/Os are
internally failsafe with no diode connecting them to AVDD.
Parameter Min. Typ. Max. Unit
Voltage (AVDD) 2.6 2.8 3.5
V
IO (IOVDD)
(1)
1.6 1.8/2.8 3.5
Ambient operating temperature
range without damage
(2)
-30 85 °C
1. XSHUT should be high level only when AVDD is on
2. Performances described in the datasheet are given under 23deg ambient temperature
4.3 ESD
The VL53L4CD is compliant with ESD values presented in the following table.
Table 11. ESD performances
Parameter Specification Conditions
Human body model JS-001-2012 ± 2 kV, 1500 Ohms, 100 pF
Charged device model JESD22-C101 ± 500 V
VL53L4CD
Electrical characteristics
DS13812 - Rev 3
page 16/36