AS621x
Register Description
Datasheet PUBLIC
DS000677 v2-00 • 2020-Feb-24
36 16
Figure 19:
Alert Output Functionality
6.2.6 Polarity Bit
The polarity bit configures the polarity of the ALERT output. If the polarity bit is cleared, the ALERT
output is low active while it becomes high active if the polarity bit is set to ‘1’.
Figure 20:
Polarity Bit Configuration
Polarity Bit
ALERT Output
0
Active low
1
Active high