9.47 WAKE_UP_DUR (5Ch)
Free-fall, wakeup and sleep mode functions duration setting register (r/w)
Table 131. WAKE_UP_DUR register
FF_DUR5 WAKE_DUR1 WAKE_DUR0
WAKE_THS_
W
SLEEP_DUR
3
SLEEP_DUR
2
SLEEP_DUR
1
SLEEP_DUR
0
Table 132. WAKE_UP_DUR register description
FF_DUR5
Free fall duration event. Default: 0
For the complete configuration of the free-fall duration, refer to FF_DUR[4:0] in FREE_FALL (5Dh)
configuration.
1 LSB = 1 ODR_time
WAKE_DUR[1:0]
Wake up duration event. Default: 00
1LSB = 1 ODR_time
WAKE_THS_W
Weight of 1 LSB of wakeup threshold. Default: 0
(0: 1 LSB = FS_XL / (2
6
);
1: 1 LSB = FS_XL / (2
8
) )
SLEEP_DUR[3:0]
Duration to go in sleep mode. Default value: 0000 (this corresponds to 16 ODR)
1 LSB = 512 ODR
LSM6DSO
WAKE_UP_DUR (5Ch)
DS12140 - Rev 2