13.2.5 PEDO_DEB_STEPS_CONF (84h)
Pedometer debounce configuration register (r/w)
Table 317. PEDO_DEB_STEPS_CONF register
DEB_
STEP7
DEB_
STEP6
DEB_
STEP5
DEB_
STEP4
DEB_
STEP3
DEB_
STEP2
DEB_
STEP1
DEB_
STEP0
Table 318. PEDO_DEB_STEPS_CONF register description
DEB_STEP[7:0]
Debounce threshold. Minimum number of steps to increment the step counter (debounce).
Default value: 00001010
13.2.6 PEDO_SC_DELTAT_L (D0h) & PEDO_SC_DELTAT_H (D1h)
Time period register for step detection on delta time (r/w)
Table 319. PEDO_SC_DELTAT_L register
PD_SC_7 PD_SC_6 PD_SC_5 PD_SC_4 PD_SC_3 PD_SC_2 PD_SC_1 PD_SC_0
Table 320. PEDO_SC_DELTAT_H register
PD_SC_15 PD_SC_14 PD_SC_13 PD_SC_12 PD_SC_11 PD_SC_10 PD_SC_9 PD_SC_8
Table 321. PEDO_SC_DELTAT_H/L register description
PD_SC_[15:0] Time period value (1LSB = 6.4 ms)
LSM6DSO
Page 1 - Embedded advanced features registers
DS12140 - Rev 2
page 135/172