Datasheet
Table Of Contents
± 2g / 4g / 8g / 16g Tri-axis Digital
Accelerometer Specifications
PART NUMBER:
KX132-1211
Rev. 1.0
31-Jul-2019
36 Thornwood Dr. – Ithaca, NY 14850 © 2019 Kionix – All Rights Reserved
tel: 607-257-1080 – fax:607-257-1146 893-12874-1907311605-0.2
www.kionix.com - info@kionix.com Page 8 of 31
Power-On Procedure
Proper functioning of power-on reset (POR) is dependent on the specific VDD, VDD
LOW
, T
VDD
(rise time)
,
and
T
VDD_OFF
profile of individual applications. It is recommended to minimize VDD
LOW,
and T
VDD
, and maximize T
VDD_OFF
.
It is also advised that the VDD ramp up time T
VDD
be monotonic. Note that the outputs will not be stable until VDD
has reached its final value.
To assure proper POR, the application should be evaluated over the customer specified range of VDD, VDD
LOW
,
T
VDD
, T
VDD_OFF
and temperature as POR performance can vary depending on these parameters.
Please refer to Technical Note TN027 Power-On Procedure for more information.