Datasheet

± 2g / 4g / 8g / 16g Tri-axis Digital
Accelerometer Specifications
PART NUMBER:
KX132-1211
Rev. 1.0
31-Jul-2019
36 Thornwood Dr. Ithaca, NY 14850 © 2019 Kionix All Rights Reserved
tel: 607-257-1080 – fax:607-257-1146 893-12874-1907311605-0.2
www.kionix.com - info@kionix.com Page 6 of 31
Electrical
(specifications are for operation at 2.5V and T = 25C unless stated otherwise)
Parameters
Units
Min
Typical
Max
Supply Voltage (VDD)
Operating
V
1.7
2.5
3.6
I/O Pads Supply
Voltage (IO_VDD)
SPI, I
2
C (Fast/Standard mode)
V
1.2
3.6
I
2
C (High Speed mode)
1.7
3.6
Current Consumption
(Accelerometer Only)
Operating (High Performance with Wake-up
Detection) ODR=400Hz
µA
148
Operating (Low power with Wake-up detection)
ODR=0.781Hz
1
0.53
Operating (Low Power with Wake-up detection
plus Advanced Data Path) ODR=0.781Hz
7
0.67
Standby Current Consumption
µA
0.5
Output Low Voltage
(V
OL
)
2
(IO_VDD < 2V)
V
-
-
0.2 * IO_VDD
(IO_VDD 2V)
V
-
-
0.4
Output High Voltage (V
OH
)
V
0.8 * IO_VDD
-
-
Input Low Voltage (V
IL
)
V
-
-
0.2 * IO_VDD
Input High Voltage (V
IH
)
V
0.8 * IO_VDD
-
-
Start Up Time
3
ms
2
1300
Power Up Time
4
ms
20
50
I
2
C Communication Rate
MHz
3.4
I
2
C Slave Address (7-bit)
0x1E / 0x1F
WHO_AM_I register value
0x3D
Output Data Rate (ODR)
5
Hz
0.781
50
25600
Output Signal Bandwidth (-3dB)
6
Hz
ODR/9 or
ODR/2
Table 2: Electrical Specifications
Notes:
1. Current varies with Output Data Rate (ODR) as shown in Figure 2, types and number of enabled digital engines, the average
filter control settings, and VDD. Measured with OWUF<2:0> = 0, OSA<3:0> = 0, AVC<2:0> = 1, LPSTPSEL = 1.
2. For I
2
C communication, this assumes a minimum 1.5k pull-up resistor on SCL and SDA pins.
3. Start up time is from PC1 set to valid outputs. Time varies with ODR, Power Mode, and FSTUP bit setting (see Figure 1).
4. Power up time is from VDD valid to device boot completion.
5. Typical values. ODR is user-selectable via I
2
C or SPI. See ODCNTL register for details.
6. Refers to accelerometer’s raw output data. Additional bandwidth control is available using the Advanced Data Path (ADP)
engine.
7. Measured with RMS_AVC<2:0> = 1, OADP<3:0> = 0, LPSTPSEL = 0.