Datasheet

± 2g / 4g / 8g / 16g Tri-axis Digital
Accelerometer Specifications
PART NUMBER:
KX132-1211
Rev. 1.0
31-Jul-2019
36 Thornwood Dr. Ithaca, NY 14850 © 2019 Kionix All Rights Reserved
tel: 607-257-1080 – fax:607-257-1146 893-12874-1907311605-0.2
www.kionix.com - info@kionix.com Page 22 of 31
HS-mode
To enter the 3.4MHz high speed mode of communication, the device must receive the following sequence of conditions
from the master: a Start condition followed by a Master code (00001XXX) and a Master Non-acknowledge. Once
recognized, the device switches to HS-mode communication. Read/write data transfers then proceed as described in the
sequences above. Devices return to the FS-mode after a STOP occurrence on the bus.
Sequence 5: HS-mode data transfer of the Master writing multiple bytes to the Slave
Speed
FS-mode
HS-mode
FS-mode
Master
S
M-code
NACK
Sr
SAD + W
RA
DATA
P
Slave
ACK
ACK
ACK
Sequence 6: HS-mode data transfer of the Master receiving multiple bytes of data from the Slave
Speed
FS-mode
HS-mode
Master
S
M-code
NACK
Sr
SAD + W
RA
Slave
ACK
ACK
Speed
HS-mode
FS-mode
Master
Sr
SAD + R
NACK
P
Slave
ACK
DATA
ACK
DATA
n bytes + ack.
(n-1) bytes + ack.