5.3.5.5 Gas valid status
In each TPHG sequence contains a gas measurement slot, either a real one which result is used or a dummy one to keep
a constant sampling rate and predictable device timing. A real gas conversion (i.e., not a dummy one) is indicated by the
gas_valid_r status register.
Register Name
Address
Content<bit position>
Description
gas_r_lsb
0x2B
gas_valid_r<5>
Gas valid bit
5.3.5.6 Heater Stability Status
Heater temperature stability for target heater resistance is indicated heat_stab_x status bits.
Register Name
Address
Content<bit position>
Description
gas_r_lsb
0x2B
heat_stab_r<4>
Heater stability bit