Table 14: BSEC outputs
Output
Included in
solution
Description
IAQ
ALL
Raw pressure
Raw data from sensor API bypassed to BSEC output
Raw temperature
Raw data from sensor API bypassed to BSEC output
Raw relative humidity
Raw data from sensor API bypassed to BSEC output
Raw gas resistance
Raw data from sensor API bypassed to BSEC output
Sensor-compensated
temperature
Temperature which is compensated for internal cross-
influences caused by the BME sensor
Sensor-compensated relative
humidity
Relative humidity which is compensated for internal cross-
influences caused by the BME sensor
Ambient temperature
Ambient temperature after compensating the influence of
device (where BME680 is integrated in) heatsources
Ambient relative humidity
Ambient relative humidity after compensating influence of
device (where BME680 is integrated in) heatsources
IAQ (0-500)
Indoor-air-quality
Accuracy status
Accuracy status of IAQ, ambient termpature/humidity
Stabilization time status
Indicates if the sensor is undergoing initial stabilization during
its first use after production
Run in status
Indicates when the sensor is ready after after switch-on