User Manual

ThingMagic Nano User Guide 52
www.JADAKtech.com
FAULT_NO_PROTOCOL_DEFINED 401h A command was received to
perform a protocol command but
no protocol was initially set. The
reader powers up with no
protocols set.
A protocol must be set before the
reader can begin RF operations.
FAULT_INVALID_PROTOCOL_SPECIFIED 402h The protocol value was set to a
protocol that is not supported with
the current version of software.
This value is invalid or this version of
software does not support the
protocol value. Check the
documentation for the correct values
for the protocols in use and that you
are licensed for it.
FAULT_WRITE_PASSED_LOCK_FAILED 403h During a Write Tag Data for
ISO18000-6B or UCODE, if the
lock fails, this error is returned.
The write command passed but
the lock did not. This could be a
bad tag.
Try to write a few other tags and
make sure that they are placed in the
RF field.
FAULT_PROTOCOL_NO_DATA_READ 404h A command was sent but did not
succeed.
The tag used has failed or does not
have the correct CRC. Try to read a
few other tags to check the hardware/
software configuration.
FAULT_AFE_NOT_ON 405h A command was received for an
operation, like read or write, but
the RF transmitter was in the off
state.
Make sure the region and tag protocol
have been set to supported values.
FAULT_PROTOCOL_WRITE_FAILED 406h An attempt to modify the contents
of a tag failed. There are many
reasons for failure.
Check that the tag is good and try
another operation on a few more tags.
FAULT_NOT_IMPLEMENTED_FOR_THIS_P
ROTOCOL
407h A command was received which
is not supported by a protocol.
Check the documentation for the
supported commands and protocols.
FAULT_PROTOCOL_INVALID_WRITE_DAT
A
408h An ID write was attempted with
an unsupported/incorrect ID
length.
Verify the Tag ID length being written.
FAULT_PROTOCOL_INVALID_ADDRESS 409h A command was received
attempting to access an invalid
address in the tag data address
space.
Make sure that the address specified
is within the scope of the tag data
address space and available for the
specific operation. The protocol
specifications contain information
about the supported addresses.
FAULT_GENERAL_TAG_ERROR 40Ah This error is used by the GEN2
module. This fault can occur if the
read, write, lock, or kill command
fails. This error can be internal or
functional.
Make a note of the operations you
were performing and contact
rfid-
support@jadaktech.com.
Protocol Fault Errors (Continued)
Message Code Cause Solution