User Manual

LDT with Crimps Vibration Sensor/Switch
LDT0-028K Piezo Vibration Rev 1 www.meas-spec.com 10/13/2008
4 of 4
The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for
inaccuracies. Furthermore, this information does not
convey to the purchaser of such devices any license under the patent rights to the manufacturer. Measurement Specialties, Inc. reserves the right to make changes without further notice
to any product her
ein. Measurement Specialties, Inc. makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does
Measurement Specialties, Inc. assume any liability arising out of the application or use of any
product or circuit and specifically disclaims any and all liability, including without limitation
consequential or incidental damages. Typical parameters can and do vary in different applications. All operating parameters must be validated for each custome
r application by
customer’s technical experts. Measurement Specialties, Inc. does not convey any license under its patent rights nor the rights of others.
ordering information
Description
Part Number
LDT0-028K 1002794-0
LDTM-028K 1005447-1
North America
Measurement Specialties, Inc.
1000 Lucas Way
Hampton, VA 23666
Sales and Customer Service
Tel: +1-800-745-8008 or
+1-757-766-1500
Fax: +1-757-766-4297
Technical Support
Email: piezo@meas-spec.com
Europe
MEAS Deutschland GmbH
Hauert 13
44227 Dortmund
Germany
Sales and Customer Service
Tel: +49 (0)231 9740 21
Technical Support
Tel: +49 (0)6074 862822
Email: piezoeurope@meas-spec.com
Asia
Measurement Specialties (China), Ltd.
No. 26 Langshan Road
Shenzhen High-Tech Park (North)
Nanshan District
Shenzhen, China 518107
Sales and Customer Service
Tel: +86 755 3330 5088
Technical Support
Email: piezo@meas-spec.com
TABLE
4
: LDT0 Clamped at Different Lengths (See Fig. 4)
Length Beyond
Clamp
Resonant
Frequency
Settling Time
(5 cyc)
20 mm (no clamp)
180 Hz
28 msec
16 mm
250 Hz
20 msec
11 mm
500 Hz
10 msec
7 mm
1000 Hz
5 msec
Experiment #4
LDT0 Clamped at Different Lengths
-
using simple clamping fixture, the vibration
sensitivity was measured (as in (1) above) as
the clamp was moved to allow different "free"
lengths to vibrate. The sensor may be "tuned"
to suit specific frequency response
requirements (see Table 4, Fig. 4).